Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Cardiol ; 95(10): 1267-70, 2005 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-15878011

RESUMO

Ultrasound measurements, including xiphoid-to-pericardial distance and deployment angle, were made on human fetuses as a function of gestational age for the purpose of assessing the likelihood of 3 failure modes of a monolithic fetal pacemaker, including primary positioning failure due to device length and secondary dislodgement failure due to somatic growth. The small variation of the measurements over the gestational age range relevant to device implantation for the major indications of the device (for complete heart block complicated by hydrops and for bradycardia risk after fetal surgery or intrauterine intervention) predicts a small likelihood of these failure modes.


Assuntos
Ecocardiografia/normas , Feto/anatomia & histologia , Marca-Passo Artificial , Ultrassonografia Pré-Natal/normas , Desenho de Equipamento , Feminino , Idade Gestacional , Humanos , Gravidez , Valores de Referência
2.
Pacing Clin Electrophysiol ; 26(4 Pt 1): 805-11, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12715839

RESUMO

Prenatal sudden cardiac death and hydrops fetalis are often due to complete heart block. However, no pacing modality exists for intrauterine application for fetal bradycardia. A prototype lead for a novel fetal pacemaker has been developed and used in a direct pacing model. It has been demonstrated that the lead can be safely and successfully deployed using a hypochondriac and transdiaphragmatic or subxiphoid approach. Pacing with ventricular capture was evident with the widening of QRS duration from 50.2 +/- 9.8 to 95.1 +/- 12.8 ms (P = 0.0001). Further studies by echocardiogram revealed an increase in the pulse with pacing, confirming pacing. This study documents proof-of-concept for closed thorax over-the-wire deployment of a novel lead design applicable to fetal pacing. By combining the lead design with microcircuitry and a small power source, it is possible to create a monolithic fetal pacemaker system capable of being deployed in utero.


Assuntos
Estimulação Cardíaca Artificial/métodos , Bloqueio Cardíaco/terapia , Hidropisia Fetal/terapia , Marca-Passo Artificial , Animais , Ecocardiografia , Eletrocardiografia , Desenho de Equipamento , Bloqueio Cardíaco/complicações , Hidropisia Fetal/etiologia , Cuidado Pré-Natal , Ratos , Ratos Sprague-Dawley
3.
Biosens Bioelectron ; 18(1): 11-21, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12445440

RESUMO

To study in vivo modification of the SAM equivalent circuit when a highly ordered SAM is used as a bioelectrode, dodecanethiolate SAM-Au intramuscular electrodes were studied in living rat heart in a challenging in situ perfused rat model by impedance spectroscopy, cyclic voltammetry, and neutron activation analysis (NAA). The SAM layer experienced disintegration in vivo biological system, as NAA detected the presence of Au atoms that had leached into the surrounding living tissue. Therefore, the underlying Au surface became exposed during biological implant. Study by impedance spectroscopy, however, revealed perfect capacitive behavior for the SAM, similar to in vitro behavior. Electrodes showed a pure capacitive Nyquist plot with 86.1-89.4 degrees near-vertical line segments as the equivalent circuit locus, as for a parallel plate capacitor. Impedance magnitude varied linearly with 1/omega excluding diffusionally limited ionic charge transport. There was no diffusional conductive element Z(W infinity ) or spatially confined Warburg impedance Z(D). The effect of in vivo exposure of a highly ordered SAM is a 'sealing over' effect of new defects by the binding of proteinaceous or lipid species in the biological milieu, a fact of significance for SAM electrodes used either as pacemaker electrodes or as a platform for in vivo biosensors.


Assuntos
Técnicas Biossensoriais , Eletrodos , Coração/fisiologia , Lauratos/metabolismo , Animais , Técnicas Biossensoriais/instrumentação , Ouro/metabolismo , Masculino , Ratos , Ratos Endogâmicos WKY , Compostos de Enxofre/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...